Unsweetened
concentrated milk is known as evaporated milk and manufactured practically in
the same manner as the sweetened condensed milk. In this product no sugar is
added as preservative. To achieve preservation the product is sterilized by heat
after concentration and sold in the hermetically sealed container in which it
has been sterilize.
Flow Diagram of Manufacture of Evaporated Milk |
i) Receiving milk/filtration/clarification/standardization: The raw milk used in the preparation of evaporated milk is treated in a similar manner to that which applies in case of sweetened condensed milk as discussed earlier. It is important that the raw milk should be of very good quality in order to ensure that it is free from any heat resisting microorganisms. Only fresh milk can be used since, if the acidity of evaporated milk is above normal it will clot or curdle during sterilization and will thus be rendered un-saleable.
ii)
Prheating/Forewarming of milk: To improve the heat
stability of concentrated product and for imparting optimum viscosity to the
finished product the fluid milk is preheated before it is condensed. Milk may
be preheated either at 95-1000 C for few minutes (5-10)
or at 140-1450 C with not holding time.
iii)
Concentration: Preheated milk is concentrated in an evaporator. Multiple effect
evaporators are used for handling large amount of milk to have continuous operation.
iv)
Homogenization: After concentration the milk is homogenized. Fat separation in
evaporated milk during storage is a major defect. This defect can be reduced or
eliminated by homogenization of condensed milk. Homogenization refers to a
process of forcing milk under pressure through equipment called homogenizer.This
is an essential part of production of evaporated milk. The homogenizer reduces
the mean size of the fat globules in the milk so that they are uniformly distributed
in milk and do not rise to the top to form the creamy layer during storage. In raw
milk, the diameters of the fat particles (globules) vary from 1 to 20 micron
while a diameter of about 2 micron or less is required to keep the fat distributed
uniformly. In this process milk is forced through a small orifice at a high
pressure by means of a positive displacement pump. The mechanical forces, which
are set up as the fat particles pass quickly through the orifice,cause the
particles to split. Condensed milk removed from evaporator is passed through
two stage homogenizer at about 50°C with a pressure of 175 kg/sq. cm at first
stage and 35 kg/sq cm at second stage.
v)
Cooling: After homogenization concentrated milk is cooled to 5°C and
held in storage tank. Stabilizing salts may be added to concentrated milk in
tank as indicated by pilot sterilization test.
vi)
Pilot Sterilization: The purpose is to determine the amount and type of chemical stabilizers
to be added to any given batch of condensed milk for most satisfactory heat
stability. Heat coagulation of milk is influenced by many factors such as initial
quality of raw milk, fore warming, concentration and sterilization. In raw milk
it has been suggested that salt balance of milk i.e. ratio of calcium +Magnesium
to citrate + Phosphate is important for the stability of milk towards heat. If
the ratio of Ca + Mg/Citrate + Phosphate is disturbed the heat stability may be
affected. The more common cause of heat coagulation is the disturbed salt
balance. Depending on the location of pH of maximum stability with respect to natural
pH of concentrated milk either sodium salt of orthophosphate (disodium
phosphate) or calcium chloride/monosodium phosphate are used as stabilizers.
This is the basis of a process of pilot-sterilization in which various quantities
of selected stabilizers are added to the concentrated milk in 170 ml (60 oz)
tins which are then sterilized and the condition of the product carefully examined
in order to determine whether any stabilizer is necessary and if so in what
amount it should be used. Depending upon the type of milk and the processing
condition used 100 to 300 gm of stabilizing salts per 100 kg of evaporated milk
may be needed to improve the heat stability. Calculated amount of salt is added
to the evaporated milk in the form of a solution using just enough water to
dissolve it.
vii)
Packaging: The evaporated milk is filled in suitable cans or containers
either manually or mechanically. It is essential that the packaging is done as
quickly as possible. After cans have been filled they should be sealed
immediately. The sealing process requires care, as the seal has to withstand
the heat and pressure of sterilization.
viii)
Sterilization: The object is to destroy all bacteria their spores and enzymes
thereby preserve the product for a longer time. In addition sterilization
process is also used to increase the viscosity and improve body and texture to
give a creamy consistency to the product.
Two important
factors in sterilization process are:
- The temperature attained
- The period during which this temperature is maintained.
The temperature
time of heating during sterilization should be such as to ensure sterility
consistent with sufficient body and texture without causing objectionable discolouration
or excessive cooked flavour.
Two systems are in
common use for sterilization:
Batch
Sterilization: This method is suitable for small scale operation and is also useful
for cans of various sizes. In this system the cans leaving the filling machine
are placed in racks. The racks are then loaded into a steam-tight boiler. The
racks are moved by a revolving mechanism, which keeps them in motion throughout
the process,the speed of rotation varies between 6- 12 revolutions per minute.
Steam is admitted in to the sterilizer until the temperature reaches 118 °C and
the sterilizer is maintained at this temperature for not less than 15 min.
After sterilization is completed, the steam is shut off and cans are cooled to
25- 30 °C either by means of water spray or by immersing in
cold water. After cooing the cans are passed through an oscillating machine,
which breaks up any curd formed during the process of sterilization and retains
the smooth homogeneous texture of evaporated milk.
Continuous
Sterilization: This is used for large scale continuous operation. This system
consists of many compartments, which are maintained at different temperatures/
pressures. The filled cans entering the apparatus roll through the chambers by
means of spiral track, which ensures that the heat distribution to each can is
uniform. This rolling motion of cans takes the place of the methods of
agitation provided in the batch method. The filled cans are preheated before
they pass to the main sterilizing section. The movement of cans is controlled
so that they remain in the sterilizing chamber for 15 min. After sterilization
process is complete the cans pass to the cooling
section, which under similar pressure conditions to those of the sterilizer.Both systems have
their merits and demerits. During sterilization the temperature of evaporated
milk is raised rapidly to 116-118°C and held at this temperature for 15 minutes
and their cooled.
Storage:
After sterilization cans of evaporated milk are unloaded from
the sterilizer, and cooled by water spray. The cans are then shaken
mechanically to break any curd or lump which might have formed during
sterilization to have homogenous consistency. Excessive shaking is avoided as
it may decrease viscosity. As evaporated milk is a sterilized product it may be
stored at or below room temperature. The present trend is to store at below
room temperature to check deterioration in quality and thereby prolong keeping
quality.
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.