i.
Sampling Personnel:
Proper sampling
depend mainly on the capabilities of sampling Personnel and they should be:
- Authorized
- Properly equipped
- Properly trained for drawing samples for chemical and bacteriological analysis.
- Free from infectious diseases.
- Physically and mentally fit.
ii.
Sample
The term “sample”
not only refers to the operation of obtaining representative material but also
to the units selected, as well as to the portion analyzed. Of particular
importance is the fact that the testing laboratory does not ordinarily become
involved in the process until it receives the physical sample(s).
A random sample is
one where every unit in a population has an equal chance of being incorporated
into the selected sample. Adequate numbers to be drawn as per requirements.
Haphazard way of sampling and also sampling at convenient positions/points
should be avoided.
iii.
Involvement of Laboratory in Sampling
Sampling of food is
usually the responsibility of a separate group of personnel in the laboratory.
In commercial and public Laboratories the sampling personnel are generally not
mixed with the testing personnel. Despite the separation, testing personnel
usually can, and should, participate in preparing instruction, particularly with
regard to the more scientific aspects of the number of units that should be taken,
where they should be taken, how much material should be in each sample unit,
the type of containers to be used, and how the samples should be transported to
the laboratory.
Despite the
availability of instructional manuals, the sample collector must have a basic
understanding of the principles of sampling to avoid common mistakes,which
could result in an invalid or non-reproducible measurement.Different values
obtained with different samples from the same consignment are unfortunately
often ascribed to poor analytical work or to unsatisfactory methods of analysis
rather than to the generally more likely cause of either improper sample and/or
inherent variability of the lot.
iv.
Sampling Equipment Modification
The varied
properties of foods, and the physical states and mixture, in which they are
found, require that a sampling person carry many types of sampling equipment. Guiding
factor for sampling equipment should be taken from National and International
Standards. But in many cases, sampling persons must improvise and use that equipment
is available to them. It is up to the testing personnel to review such
improvisations to be sure that substitutions do not introduce such substantial sampling
errors as to invalidate the analytical results.
v.
Sealing and Labeling
- Nature of product
- Date___________ Time____________
- Batch No./Code No.
- Manufacturing place
- Purpose of sampling
- Sample taken from
- Sample Code
- Condition of sample – Storage condition of product at the time of sampling.
- Directions for storage
- Care during transport
- Sampled by – Name & Designation
- Place samples to be sent
vi.
Sample Container
Sample containers
should be inert and capable of being closed/sealed and should not allow further
contamination. Glass containers are good, except that they are fragile and can
break if not handled properly. If light may alter a component, opaque
containers must be used or transparent ones must be wrapped in an opaque
material, such as aluminium foil or brown paper. Plastic bags can also be used
in some cases. Solid or semi-solids require wide mouth bottles. For Liquids–
narrow mouth bottles can be used.
vii.
Preservation of Samples
The most convenient
method for preserving samples prior to transportation and storage is with
chemical preservatives. On the label of such samples the details of the
preservative with name and quantity have to be mentioned.When applicable,
frozen storage (eg., Ice creams) is an excellent method for preserving samples.
However, freezing ruptures cells, and enzyme activity thereafter may be
substantially accelerated during de-frosting/warming. Samples for microbiological
analysis should preferably be transported at less than 7°C.
viii.
Microbiological Sampling
Sampling equipment
and sample containers should be sterilized. It is done by autoclaving (120o C
for 20 mts) or by keeping in hot air oven (100o C
for 2 hours). While carrying these material care should be taken to avoid
contamination.Immersion of sampling equipment in rectified spirit or ethyl
alcohol or ignition in alcohol are also suggested before sampling. Because of
these extra precautions it is advisable these samples are not considered for
organoleptic evaluation.
ix.
Storage and Transportation of Samples
During
storage/transportation, three types of changes which most likely to occur are:
1. Changes in
composition of samples through evaporation or absorption of moisture,
evaporation of other volatile constituents, oxidation, etc.
2. Changes in
composition of samples through action of enzymes (especially through activity
of hydrolytic enzymes)
3. Changes in
composition of samples through action of microorganisms.Therefore
bacteriological samples are to be stored and transported in cold condition,Dry
samples to be stored in less humid conditions. Storage instructions on the label
has to be read thoroughly and followed.
Ideally, samples
should be analyzed promptly after collection, but rarely it is possible. Hence
adequate care should be taken in storing samples at the laboratory before
analysis.
x.
Milk Sampling Equipment
i)
Manual agitation in small vessels
For mixing liquids
in small vessels (e.g. in buckets and cans) a stirrer normally known as plunger
is suitable. A plunger is disc with holes with a SS rod welded in the middle of
the disc as a handle. The length of the rod and the diameter of the disc depend
on the size of the container. Normally 1 meter length plunger is used.
ii)
Manual mixing in large vessels
Two meters length
plunger is used for mixing milk in road/rail tankers.
xi.
Dippers
Dipper is a SS
tumbler with a handle welded on one side. Dippers of holding capacity ranging
from 50 to 200 ml. are available in the market. Depending on the depth of the
container suitable dipper can be used.
xii.
Borers
Borers of
sufficient length to reach the bottom of the product container. The borer shall
be made entirely of polished stainless steel. The edge of the borers is sharp and
serve as a scraper.
xiii.
Butter Triers
Butter triers of
sufficient length to pass diagonally to the bottom of the product container,
and of dimensions suited for the purpose envisaged.
xiv.
Cheese Triers
Cheese triers of
shape and size appropriate to the cheese to be sampled.
xv.
Spoon, Knief or Spatula Orice Scoop
Smooth surface and
of sufficient size.
xvi.
Cutting Wire of Sufficient Size and Strength.
- Preferably of SS, no crevices.
- Surfaces smooth
xvii.
Use of Sampling Equipment
- Agitators for mixing liquids in bulk shall have a surface sufficient to produce adequate mixing of the products. In view of the different shapes and sizes of containers, no specific design of agitators can be recommended for all purposes,but they shall be designed in such a way as to avoid damage of the inner surface of the container during mixing. The extent of mixing depends on the period of time over which the milk has been at rest.
- The product to be mixed in the tank or vessel determines the technical characteristics and construction of built-in agitators.
- Removable agitators are usually provided with a propeller and are introduced into transport, road and rail tanks through the manhole.
- It is recommended that the stirrer be inclined 5º to 20º as this allows vertical mixing of the liquor as well as horizontal movement.
- Thoroughly mix the milk by stirring or plunging (Plunger) in small vessels, milk buckets and cans.
- In milk tanks or vats mechanically agitate the milk for at least 5 min. until sufficient homogeneity is obtained. If the tank is equipped with a periodical, timeprogrammed agitation system, sampling may be carried out after only a short duration of agitation.
- In those instances where the propeller of the agitator is close to the surface of the milk, do not use the agitator since this is likely to lead to the formation of foam or churning.
- Mixing using a plunger or a removable agitator to be used in road, rail tanks or vessels of similar size shall be performed as follows:
When samples are taken
within 30 min. after filling the container, mix the milk for at least 5 min. by
plunging or stirring with an agitator, when the milk has been stored in the
tanker for a longer period of time, mixing shall be extended to at least 15
min.
- In a large vessel with a bottom discharge outlet or a sampling cock installed at another place, there may be, at the discharge outlet, a small quantity of milk, which is not representative of the whole contents even after mixing.
Accordingly samples
shall preferably be taken through the manhole. If samples are taken from the
discharge outlet valve or the sampling cock, discharge sufficient milk to
ensure that the samples are representative of the whole.
- The efficiency of the method of mixing applied in any particular circumstances shall be demonstrated as being adequate for the purpose of the analysis envisaged; the criterion of mixing efficiency is the reputability of analytical results from different parts of the whole, or from the outlet of the tank at intervals during discharge. To be precise samples from top, middle, bottom or any part of the container should show the same test results.
- Samples should be proportionate to the quantity in the container
xviii
Sampling of Same Products
i)
Silo/Storage Tank
Depending on the
capacity, agitation is done with the help of mechanical agitator fitted into
the silo/tank. Time of agitation varies depending on the capacity. After the
agitation is complete, allow the flow of 2 to 3 liters of milk through sampling
cock into a bucket. Rinse the sample bottle with fresh flow of milk. Drain the
milk into the bucket. Then draw sample. Always draw samples in duplicate. The bottles
have to be properly labelled before drawing the samples. Adequate precautions
have to be taken before drawing sample for microbiological testing.
ii)
Road Tankers
Check the
conditions of the seals. Open the manhole lid. Observe for any foreign matter.
If it is free from foreign matter, plunger for about 15 minutes in all
directions.Avoid mixing of air into milk. Take samples as explained in ‘Silo/Storage
Tank’.
iii)
Milk Powder
0.0 After every 70
bags, select one bag of powder for sampling. Normally one truck load of milk
powder contains 15 MT.
iv.
Butter
After every 70
cartons, select one carton of butter for sampling. Normally one truck load of
butter contains 15 MT.
v.
Milk Powders/Butter
For containers upto
25 Kgs :
- Select 4 samples in 100 containers/Packs. Take about 200 grams powder of sample . One is kept for microbiological purpose.
- For composite sample add 50 grams of powder from each sample. Mix well and take 200 grams as sample..
- Always draw sample in duplicate. In case of doubt the second sample can be analysed.
Bottles should be
sterile and air tight. On the bottles mark clearly whether it is for chemical examination
or for microbiological examination
vi.
Ghee
In the trade 15 Kgs
tins are popular. One tin for every 50 tins may be sampled.All the containers
in a single consignment belonging to the same batch of manufacture shall be
sampled together.Sampling tubes made
of stainless steel should be used for large containers.If the contents are in
molten condition gently make the tin upside down 5 to 6 times and then draw a
sample.If the contents are in solid a semisolid condition use the sampling tube
as a borer and skillfully pull out the contents from the entire depth of the
container. Ensure all the three portions- bottom, middle and top layers are
properly represented in the sample.
Take individual
samples from each container. Draw about 50 ml or 50 gm sample from each
individual sample and put into a sterile dry container. Melt to about 40°C. Mix
well and draw two samples. Each sample should be about 200 ml
vii. Products
like Ice-cream, Ice Candies, Lollies and other frozen products
are always stored
under frozen condition( less than minus 18 degree.C). Such samples should
preferably be transported in frozen condition to the laboratory for testing.
Dry ice can be used.
viii.
Dried milk
If the drier is
running continuously, draw samples at an interval of 30 minutes and test for
colour, flavour ,
taste and moisture. More moisture than the dairy standard means less shelf
life.
In the case of
small packs of one litre or below like milk, flavoured milk, ice cream, table
butter, ghee etc. it is always safe to take the entire pack as a sample.Follow
batch wise sample. For every 500 units draw one sample.